Agilent manual step attenuator






















Agilent B Step Attenuator SMA (f) Your Price: $ In Stock Ships in 1 to 2 Business Days. Qty. Keysight / Agilent B Step Attenuator, dc to 18 GHz, 0 to 70 dB, 10 dB steps. The B dc to 18 GHz manual step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 10 dB steps from 0 to 70 dB.  · • Agilent Technologies E Digital Test Card (No Substitution) • HP/Agilent G Programmable. Step Attenuator. Attenuation: 0 to 70 dB. Frequency range: dc to 4 GHz • HP/Agilent A Step Attenuator. Driver • HP/Agilent EA/B Phase Noise. Measurement System. 2, 3. Agilent User Manual Software. Frequency range: 0 to 4 GHz. Please Confirm. Confirm your country to access relevant pricing, special offers, events, and contact information.


item 5 Agilent A Manual Step Attenuator, Opt 2, DC to 4 GHz, 0 to 70 dB 5 - Agilent A Manual Step Attenuator, Opt 2, DC to 4 GHz, 0 to 70 dB. $ +$ shipping. item 6 Agilent A Step Attenuator 70dB Frequency Range DC - 4GHz RF Power 1W CW 6 - Agilent A Step Attenuator 70dB Frequency Range DC - 4GHz RF Power 1W CW. This data, measured with an Agilent automatic network analyzer, can be ordered as Option XX-UK6. Attenuation switching and control These units feature the same small solenoids and switching circuits as the Agilent Technologies /5/6/7 step attenuator family. Switching time is a maximum of 20 milli-seconds, including contact set-tling time. The Keysight (formerly Agilent) B dc to 18 GHz manual step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 10 dB steps from 0 to dB. Precision gold-plated leaf springs ensure long life (over 5 million cycles) and very high attenuator repeatability (typically dB).


The Agilent B is a ohm coaxial step attenuator. The attenuation can be varied in 1 dB steps. The attenuation shown on the control knob is the additional attenuation added in the signal path over the insertion loss of the attenuator in the 0 dB position. Agilent B instruments are four-section attenuators with a range of 0 dB to 11 dB in 1 dB steps. Agilent A/B, A/B, A/B Operating And Service Manual 1 Instrument Definition This manual contains installation, operation and test information for the Agilent Technologies A/B, A/B, and A/B step attenuators. The instruments covered by this manual have a two-part serial number. The. Agilent/HP Step Attenuator Repair. We offer sales and expert repair services for HP / Agilent / Keysight Step Attenuators operating up to 50GHz. Every attenuator ships with an industry-leading 1-Year Warranty and network analyzer test plots that show the actual attenuation of each pad across the entire operating frequency of the attenuator.

0コメント

  • 1000 / 1000